ha-usr-modbus-bridge

USR Modbus Bridge logo

USR Modbus Bridge card

hacs_badge License: MIT IoT Class GH-release BuyMeCoffee


Home Assistant integration for RS-485 pool equipment — variable-speed pool pumps (Modbus master mode), Hayward / Silverline inverter heat pumps (touch-panel listener mode), and EMEC pH/Redox pool controllers (ERMES-family ASCII protocol, full read + write) — with two hardware approaches to connect them to Home Assistant.

⚠️ The EMEC WDPHRH must be on its own physical RS-485 bus (own USR-TCP232 gateway + own MAX485/MAX13487E), because its 500 ms heartbeat traffic and 38400 baud rate are incompatible with sharing a Modbus RTU bus. See EMEC WDPHRH controller below.


Table of contents


Supported devices

Device Manufacturer Protocol Baud Address Mode Status
InverFlow Eco Madimack / Aquagem Modbus RTU 8N1 9600 0xAA (170) Polled (we are master) ✅ Fully supported
Pool heat pump Hayward / Silverline Touch-panel RTU 8N1 9600 0x02 (fixed) Listener (pump is master) ✅ Sensors + climate
WDPHRH pH/Redox controller EMEC ERMES-family ASCII 8N1 38400 01 (RS-485) Polled with heartbeat ✅ Full read + write (setpoints, modes, alarms, reset)

The InverFlow Eco is an OEM version of the Aquagem InverPro pool pump. All variants sharing the same controller (Madimack, Aquagem, Fairland INVERX, etc.) should be compatible.

The Hayward pool heat pump support targets recent Hayward / Silverline inverter units whose Wi-Fi dongle speaks the Modbus-framed touch-panel protocol. On this bus the pump is the master and the integration emulates the Wi-Fi module (address 0x02), so it runs a persistent listener instead of polling. It exposes a full climate entity (on/off, heat/cool/auto, setpoint) plus temperature / current / fan sensors. It is not for the older single-wire PC1000/PC1001 controllers.


Two ways to connect

Both options give you the same Home Assistant entities and the same local, cloud-free control. The difference is in the hardware between your pump and Home Assistant.

Option A — USR TCP bridge (recommended for most users)

A USR-TCP232-304 (or compatible) converter sits on the RS-485 bus and bridges it to your home network over TCP. The HA integration connects to it directly — no additional hardware required beyond the converter.

Home Assistant
     │
     │ TCP  (LAN)
     ▼
USR-TCP232-304
192.168.0.x:8899
9600 baud / 8N1
     │
     │ RS-485
     ▼
InverFlow Eco
addr 170 (0xAA)

Pros: simple setup, no firmware to maintain, one device for multiple pumps on the same bus. Cons: requires a separate Ethernet/WiFi device on the network.


Option B — ESP32 + MAX485 (ESPHome)

An ESP32 with a cheap MAX485 TTL module connects directly to the pump RS-485 bus over GPIO. ESPHome handles the Modbus protocol and exposes entities to Home Assistant via the native API.

Home Assistant
     │
     │ ESPHome native API  (WiFi)
     ▼
ESP32 + MAX485 module
GPIO14=TX  GPIO15=RX  GPIO23=DE/RE
     │
     │ RS-485
     ▼
InverFlow Eco
addr 170 (0xAA)

Pros: ~5€ total hardware cost, no extra device on the network, fully local. Cons: one ESP32 per RS-485 bus segment, requires flashing ESPHome firmware.

The ESP32 wiring below is for the InverFlow pump. For the Hayward heat pump on an ESP32, use the dedicated repo ha-esphome-hayward (auto-direction transceiver, climate entity included).


Comparison

Option A — USR TCP bridge Option B — ESP32 + MAX485
Hardware cost ~25-40€ ~5-10€
Setup complexity Low — web UI config Medium — ESPHome flash
Multiple devices on same bus ✅ Yes ⚠️ One bus per ESP32
Firmware to maintain ❌ None ✅ ESPHome OTA
HA integration Custom component (this repo) ESPHome native API
Network dependency TCP over LAN WiFi
Wake-up mechanism Automatic (coordinator) Boot + 5min interval + button

InverFlow Eco — Modbus register map

Confirmed by RS-485 capture session and Tuya/Modbus correlation (2026-05-08).

Read registers (FC=03, device address 0xAA / 170)

Register (hex) Register (dec) Key Description Notes
0x07D1 2001 error_code Error bitmask 0=no error — also the wake-up register
0x07D2 2002 op_condition Operation condition bitmask bit0=1 → running
0x07D3 2003 speed_pct Running capacity % Actual speed, not setpoint
0x07D4 2004 power_w Instant power W Confirmed vs Tuya DPS 5
0x07D7 2007 const_2007 Firmware constant (~88) Fixed value, meaning unknown
0x07D8 2008 const_2008 Firmware constant (~20) Fixed value, meaning unknown
0x07D9 2009 const_2009 Firmware constant (~28) Fixed value, meaning unknown

Write register (FC=06)

Register (hex) Register (dec) Description Range
0x0BB9 3001 Speed setpoint % 0=stop, 30–100=run

Speed is snapped to the nearest 5% and clamped to 30% minimum when running.

Error bitmask (register 2001)

Bit Error
0 DC voltage abnormal
1 AC current sampling circuit failure
2 Phase-deficient protection
3 Master drive error
4 Heatsink sensor error
5 Heatsink overheat
6 Output current exceeds limit
7 Input voltage abnormal
8 No water protection
9 Panel↔master comm failure
10 Panel EEPROM read error
11 RTC read error
12 Main EEPROM read error
13 Motor current detection error
14 Motor power overload
15 PFC protection

ON/OFF strategy

The InverFlow Eco has no dedicated ON/OFF Modbus register:

  • turn_off → write 0 to register 0x0BB9
  • turn_on → write last known speed (default 80%) to register 0x0BB9

Running state is determined by reading op_condition bit 0.

Wake-up behaviour

After a power cut or extended RS-485 silence, the pump stops responding. A single FC=03 read on register 0x07D1 re-activates the RS-485 interface. Both solutions implement this automatically.


Hayward pool heat pump

Unlike the InverFlow (which the integration polls as a Modbus slave), the Hayward heat-pump control board is itself the master: it broadcasts its sensor block and polls each peripheral. The integration therefore emulates the Wi-Fi module on the bus:

  • it keeps a persistent connection to the USR gateway and answers the board's status polls with the correct device identity (reg 3009 = 0x0102) and a small reply hold-off (~60 ms, like the real touch panel);
  • it mirrors the pump's settings and, to apply a change, raises a flag, serves the edited settings block when the board reads it back, then the board commits.

Connection (USR gateway)

Same USR-TCP232 wiring and web-UI settings as the InverFlow (TCP Server, 9600 8N1, RFC2217 off). Wire the pump's RS-485 A/B/GND to the USR A+/B-/GND.

Setup in Home Assistant

Settings → Devices & Services → Add Integration → USR Modbus Bridge

  1. Gateway step: IP / port / 9600 / 8N1 (as for any device).
  2. Device type step: choose Hayward pool heat pump, give it a name. The Modbus address is fixed to 0x02 and is not asked (it is structural for the Wi-Fi slot).
  3. Done. Within a few seconds the settings blocks are pulled (auto-refresh) and the climate entity + sensors become available.

Options (post-setup): click Configure to tune the reply hold-off (ms) if a command is ever not picked up (50–90 ms is the useful range).

Hayward entities

Entity Type Description
Heat pump climate on/off, heat / cool / auto, target temperature, current temp (water inlet), heating/cooling action
Water inlet / outlet Sensor Loop temperatures
Suction / Coil / Ambient / Exhaust Sensor Circuit temperatures
Compressor current Sensor A
AC voltage Sensor V
Fan speed Sensor rpm
Per-mode setpoint memory (cool/heat/auto) Sensor (diag) Memorised setpoints from block 1091

ESP32 alternative for the heat pump

Prefer a direct ESP32 on the bus instead of a USR gateway? A dedicated ESPHome external component provides the same climate entity + sensors, standalone: ha-esphome-hayward. Use an auto-direction RS-485 transceiver (e.g. MAX13487E) — no DE pin needed.


EMEC WDPHRH controller

Full read + write support for the EMEC WDPHRH pool water controller (pH + Redox regulation with proportional or ON/OFF dosing), reverse-engineered in 2026 by sniffing the BT ETH gateway module talking to the pump over RS-485 and correlating every field with the Nimbus / MyEmec cloud UI.

Unlike the Modbus devices, the WDPHRH speaks an ASCII protocol from the ERMES family with three quirks:

  • Heartbeat every ~500 ms (34tb00 #0#\r\n) or the pump goes silent
  • Double-CR terminator on commands (3401<cmd>\r\r) — a single \r is interpreted as a malformed heartbeat and ignored
  • Distinct framing (ASCII fields separated by #, terminated by \r) so it must live on its own bus, never mixed with Modbus RTU slaves

Read reply and write ACK look like:

→ 3401setpntr\r\r
← 34gpd01&WD#0770#0730#040#000#00#0#0630#0670#050#000#00#0#setpntrend\r

→ 3401setpnw0760073004000000006300670050000000setpnwend\r\r
← 34gpd01&setpnwokend\r

The write payload is the read fields concatenated without # separators, each field zero-padded to its known fixed width.

Hardware requirement — dedicated bus

The 500 ms heartbeat traffic and the 38400 baud rate are incompatible with sharing a Modbus RTU bus (which requires ≥ 3.5-char inter-frame silence). Wire the WDPHRH on its own USR-TCP232 + own MAX13487E (or equivalent auto-direction transceiver). Terminate the bus with 120 Ω at each end.

Pump RS-485 wiring (verified from the EMEC BT MODBUS documentation):

  • Pin 1: A = RS-485+
  • Pin 2: B = RS-485−

Nimbus enrolment — probably not required, not proven

The pump was enrolled on e-nimbus.com during the reverse-engineering sessions, so writes have only been tested with an active Nimbus session in the background. It is not proven that Nimbus enrolment is required for HA writes to work — the initial #no#change replies we got early on were most likely caused by wrong command names (we were trying setpntw and changesp before discovering that the real write is setpnw).

If your unit is not enrolled and writes fail with #no#change, please open an issue — that would be the data point needed to actually pin the requirement down.

Note: ermes-server.com is being phased out; new BT ETH modules must be enrolled on e-nimbus.com if you want the cloud UI.

Setup in Home Assistant

Settings → Devices & Services → Add Integration → USR Modbus Bridge

  1. Gateway step: IP / port of the WDPHRH's USR / 38400 / 8N1.
  2. Device type step: choose EMEC WDPHRH, give it a name.
  3. EMEC controller step: RS-485 slave address (usually 1) and poll interval (10 s is a good default).

The setup step probes with a valuer query and only creates the entry if the pump answers.

EMEC entities

Everything is organised on the device page under three sections.

Main controls — the live view and the acknowledge button:

Entity Type Description
pH Sensor Live pH (device_class ph)
Redox Sensor Live Redox in mV (device_class voltage)
pH- reservoir empty Binary sensor Alarm bit a1
Chlorine reservoir empty Binary sensor Alarm bit a2
No flow Binary sensor Alarm bit a3
Standby Binary sensor Alarm bit a8
Reset alarms Button Sends resalw to clear latched alarms

Configuration — everything writable to the pump:

Entity Type Range / options Writes via
pH high / low setpoint Number 0.00 – 14.00, step 0.05 setpnw
pH high / low dose % Number 0 – 100 % setpnw
pH waiting time Number 0 – 99 min (used in ON/OFF mode) setpnw
pH working mode Select PROPORTIONAL / ON-OFF setpnw
Redox low / high setpoint Number 0 – 999 mV, step 5 setpnw
Redox low / high dose % Number 0 – 100 % setpnw
Redox waiting time Number 0 – 99 min setpnw
Redox working mode Select PROPORTIONAL / ON-OFF setpnw
Max strokes pH / Redox Number 1 – 180 P/m setskw
Passcode Number 4-digit paramw
Feeding delay Number 0 – 60 min paramw
Priority mode Select No priority / pH / Redox paramw
Dosing alarm pH / Redox threshold Number 0 (off) or ≥ 1 min alldow
Dosing alarm pH / Redox mode Select DOSE / STOP alldow
Probe failure pH / Redox threshold Number 0 (off) or 100 – 250 min allprw
Probe failure pH / Redox mode Select DOSE / STOP allprw
Flow mode Select Direct / Reverse / Disable flowsw
Flow time Number 0 – 99 min flowsw
DI Standby / pH level / Redox level is N.C. Switch Contact type N.O. / N.C. diginw
Sync clock to HA Button Pushes HA time to pump via clockw clockw

Diagnostic — troubleshooting and unmapped fields:

Entity Type Purpose
Service counter Sensor Total service hours
Service offset Sensor Internal offset
Output 1 / 2 / 3 Binary sensor Relay states from outptr
Alarm 4 / 5 / 6 / 7 (unknown) Binary sensor Un-mapped alarm bits
Dosing alarm pH / Redox enabled Binary sensor Derived (minutes > 0)
Probe failure pH / Redox enabled Binary sensor Derived (minutes > 0)
valuer field 3 (unconfirmed) Sensor Suspected current dose %, always 0 in captures — awaiting live confirmation
valuer field 4 (raw) Sensor Trailing status flag from valuer
Restart connection Button Reconnects the TCP session

Encoding convention (for reference)

Writable enums encode as small integers/strings on the wire:

  • Working mode (pH / Redox): 0 = PROPORTIONAL, 1 = ON/OFF
  • Priority: 1 = No priority, 2 = pH priority, 3 = Redox priority
  • Flow mode: 0 = Disable, 1 = Reverse, 2 = Direct
  • Dosing alarm mode / Probe failure mode: 0 = DOSE, 1 = STOP
  • DI contact type: 0 = N.O., 1 = N.C.
  • Enabled via minutes = 0: dosing alarm and probe failure are considered disabled when the corresponding minutes field is 0; setting a non-zero value both enables the feature and configures its threshold.

The write layouts of every command are documented at the top of bridge/devices/emec_wdphrh.py.


HA integration setup (Option A)

USR converter configuration

Parameter Value
Work Mode TCP Server
Local Port 8899
Baud Rate 9600
Data Size 8 bit
Parity None
Stop Bits 1
Similar RFC2217 ❌ OFF (critical — TX stays 0 if enabled)
TCP Server-kick off old connection ❌ OFF
Modbus Type None

Wiring

InverFlow connector USR terminal
PIN 6 (RS485 A / DATA+) A+
PIN 7 (RS485 B / DATA−) B−
PIN 5 (GND) GND (optional)

Installation

HACS (recommended)

  1. HACS → Integrations → ⋮ → Custom repositories
  2. Add https://github.com/Elwinmage/ha-usr-modbus-bridge as Integration
  3. Install USR Modbus Bridge → Restart HA

Manual

Copy custom_components/usr_modbus_bridge/ into your HA custom_components/ folder and restart.

Configuration

Settings → Devices & Services → Add Integration → USR Modbus Bridge

Step 1 — Gateway

Field Description
Gateway model USR-TCP232-304 / USR-TCP232-306 / USR-N510 / Other
IP address IP of the USR converter
TCP port Default: 8899
Baud rate 9600
Data bits / Parity / Stop bits 8 / None / 1

Step 2 — Device

Field Description
Device type InverFlow Eco
Modbus address 170 (shown in pump menu)
Friendly name e.g. "Pool pump"
Poll interval 2–300 s (default 10 s)

Options (post-setup): click Configure to change baud rate, bus parameters, or poll interval without re-adding the integration.


ESPHome setup (Option B)

Hardware

MAX485 module

Component Notes
ESP32 dev board Any ESP32 board
MAX485 module C25B or equivalent (~2€)

Wiring

ESP32 GPIO14 (TX) ──→ MAX485 DI
ESP32 GPIO15 (RX) ←── MAX485 RO
ESP32 GPIO23      ──→ MAX485 RE  ┐ tie together
ESP32 GPIO23      ──→ MAX485 DE  ┘
MAX485 VCC        ←── 5V
MAX485 GND        ──── GND
MAX485 A (DATA+)  ──── InverFlow PIN 6
MAX485 B (DATA−)  ──── InverFlow PIN 7

RE and DE are tied together on the module — GPIO23 HIGH = transmit, LOW = receive.

Configuration

Full YAML: doc/inverflow_esphome.yaml

# Flash
esphome run doc/inverflow_esphome.yaml

Entities

Both options expose equivalent entities:

Entity Type Description
Power Switch ON (restores last speed) / OFF (setpoint=0)
Speed Sensor Actual running speed %
Power Sensor Instant power consumption W
Speed setpoint Number Target speed slider
Restart / Wake-up Button Force reconnect + RS-485 wake-up
Error Text sensor (diag) Decoded error bitmask from reg 2001
Firmware constants Sensors (diag) Raw firmware constants, hidden by default

Resilience & wake-up mechanism

Situation Option A (HA integration) Option B (ESPHome)
Pump asleep after power cut Wake-up ping at startup + after every reconnect Wake-up ping at boot
All registers ERR × 3 polls Auto TCP reconnect + wake-up ESPHome Modbus retry
No valid data for 5 min Auto TCP reconnect + wake-up Periodic wake-up every 5 min
Manual recovery Restart connection button Wake-up RS485 button

⚠️ Only one TCP client can connect to the USR converter at a time. Never run diagnostic scripts (socat, Python monitor) while the HA integration is active.


Adding new devices

  1. Create custom_components/usr_modbus_bridge/bridge/devices/mydevice.py
  2. Subclass ModbusDevice from bridge/devices/base.py
  3. Declare READ_REGISTERS, implement set_speed(), set WAKE_UP_REGISTER if needed
  4. Register in const.py → DEVICE_PROFILES
from .base import ModbusDevice, RegisterDef

class MyDevice(ModbusDevice):
    DEVICE_KEY       = "my_device"
    DEVICE_NAME      = "My Pool Pump"
    MODBUS_ADDRESS   = 0x01
    WAKE_UP_REGISTER = 0x0001  # optional

    READ_REGISTERS = [
        RegisterDef(0x0001, "speed", "Speed", "%", 1, 0),
        RegisterDef(0x0002, "power", "Power", "W", 1, 0),
    ]

    async def set_speed(self, client, speed_pct: int) -> bool:
        return await client.write_register(self.MODBUS_ADDRESS, 0x0010, speed_pct)

    @property
    def sensor_keys(self): return ["speed", "power"]

    @property
    def switch_key(self): return "speed"

Troubleshooting

Pump does not respond after power cut → Press Restart connection (Option A) or Wake-up RS485 (Option B). The wake-up ping re-activates the RS-485 interface.

TX counter stays at 0 on USR web interface → Disable Similar RFC2217 in the USR web UI → Save → power cycle the USR physically.

All entities show unavailable → Verify no other client (socat, Python script) is connected to port 8899. Check HA logs for connection errors.

Integration does not find the device during setup → Confirm Modbus address in pump menu (InverFlow Eco default: 170). Ensure pump is powered and PIN6/PIN7 wired correctly.

ESPHome: pump not responding after ESP32 reboot → The boot wake-up ping handles this automatically. If it persists, press the Wake-up RS485 button in HA.